Walk in Cooler and Reach-in-Cabinet
WALK-IN COOLER
- Large refrigerated storage unit used in restaurants, supermarkets, and food industries.
- Maintains temperatures between 0°C to 5°C for perishable goods.
- Main Components & Their Functioning
Component | Function |
---|---|
Compressor | Pressurizes refrigerant and circulates it. |
Condenser Coil & Fan | Removes heat from refrigerant. |
Expansion Valve | Controls refrigerant flow into evaporator. |
Evaporator Coil & Fan | Absorbs heat, cooling the interior space. |
Thermostat | Maintains set temperature. |
Insulated Panels | Reduces heat loss. |
Defrost System | Prevents ice buildup on evaporator. |
- Working Principle
-
- Compressor compresses low-pressure refrigerant into a high-pressure gas.
- The condenser coil dissipates heat, turning refrigerant into liquid.
- Expansion valve reduces pressure, cooling the refrigerant.
- Evaporator coil absorbs heat, cooling the interior.
- Thermostat cycles the system on/off as needed.
- Capacity & Types
- Small Walk-in Cooler – ~1 to 5 HP (Horsepower)
- Medium Walk-in Cooler – ~5 to 15 HP
- Large Walk-in Freezer – Above 15 HP
- Care & Maintenance
- ✅ Clean condenser coils for efficient cooling.
✅ Check door seals to prevent warm air leakage.
✅ Monitor refrigerant levels for proper cooling.
✅ Defrost regularly to avoid ice buildup.
- ✅ Clean condenser coils for efficient cooling.
REACH-IN CABINET
- Definition & Application
- Smaller refrigeration unit used in commercial kitchens & grocery stores.
- Designed for frequent access to stored products.
- Temperature range: 1°C to 10°C (Chiller), -18°C to -22°C (Freezer).
- Main Components & Their Functioning
Component | Function |
---|---|
Compressor | Pumps refrigerant to maintain cooling. |
Condenser Coil & Fan | Releases heat from refrigerant. |
Capillary Tube/Expansion Valve | Controls refrigerant flow. |
Evaporator Coil & Fan | Cools the air inside the cabinet. |
Thermostat | Regulates temperature. |
Door Gaskets | Prevents air leaks. |
Defrost System | Prevents ice formation. |
- Working Principle
-
- The compressor circulates refrigerant.
- Condenser coil removes heat.
- Expansion valve lowers refrigerant pressure.
- Evaporator coil absorbs heat, cooling the air.
- Fan circulates cool air inside the cabinet.
- Thermostat regulates temperature.
- Capacity & Types
- Single-Door Reach-in Cabinet – Small kitchens (~1-2 HP)
- Double-Door Reach-in Cabinet – Medium-scale (~2-5 HP)
- Triple-Door Reach-in Cabinet – Large restaurants (~5-10 HP)
- Care & Maintenance
- ✅ Clean condenser coils & evaporator fans regularly.
✅ Check door seals for proper insulation.
✅ Ensure proper airflow inside the cabinet.
✅ Defrost system regularly to maintain efficiency.
- ✅ Clean condenser coils & evaporator fans regularly.